Guide

PortServer TS Replacement: Which Digi Connect EZ to Buy

Digi has discontinued seven PortServer TS models. Last-time-buy orders close on 30 January 2027 and the last units ship on 30 September 2027. Digi’s replacement range is Connect EZ: the EZ Mini for one port, the EZ 2 for two, and the EZ 4 TS or EZ 4 PoE for four. Match your part number in the table below, then check ports, temperature and cabling before you swap.

Digi Connect EZ serial device server family

A PortServer TS can run for years untouched. Then the end-of-life notice lands, and someone has to choose between a stock-up order and a migration, against a fixed order deadline.

Digi issued product change notice PCN 261104-03 on 4 November 2026. Seven PortServer TS models are discontinued. Last-time-buy orders are accepted until 30 January 2027 and the last units ship on 30 September 2027.

This guide maps every affected part number to Digi’s recommended replacement, flags where the swap is not like for like, and sets out the decision between buying stock and migrating. For the wider case for moving off legacy serial, read our post on modernising serial connectivity with the Connect EZ TS. The full range sits in our Digi serial and connectivity products.

Which PortServer TS models are end of life?

Seven PortServer TS models are discontinued under Digi notice PCN 261104-03: 70002041, 70001805, 70001917, 70002043, 70001806, 70001992 and 70001993. Five other models are marked not recommended for new designs but remain orderable. Digi gives component obsolescence as the reason.

Two groups, and the difference matters:

  • Discontinued (7): PortServer TS 1, TS 1 MEI, TS 1 H MEI, TS 2, TS 2 MEI, TS 2 P MEI and TS 4 P MEI. These carry the end-of-life dates below.
  • Not recommended for new designs, still orderable (5): PortServer TS 4, TS 4 MEI, TS 4 H MEI, TS 3 M MEI and Digi One SP. Digi’s notice gives these no end-of-life dates.
Digi Connect EZ 4 TS serial device server with four RJ45 serial ports

What are the end-of-life dates?

Last-time-buy orders are accepted until 30 January 2027. Last-time-ship is 30 September 2027. Last-time-buy orders are non-cancellable and non-returnable, so the quantity must be right first time.

MilestoneDate
Notice issued and effective4 November 2026
Last-time-buy orders close30 January 2027
Last-time-ship30 September 2027

Once a last-time-buy order is placed, it cannot be cancelled and the units cannot be returned. The dates apply to the seven discontinued models only.

Which Connect EZ replaces your PortServer TS?

Digi’s map is: TS 1 models to the Connect EZ Mini; TS 2 and TS 2 MEI to the EZ 2; TS 2 P MEI and TS 4 P MEI to the EZ 4 PoE; TS 4, TS 4 MEI, TS 4 H MEI and TS 3 M MEI to the EZ 4 TS. Find your part number below.

The first seven rows are discontinued. The last five are NRND (Digi’s label for not recommended for new designs) but still orderable. Extra replacements named in Digi’s notice appear in the fifth column.

Part numberPortServer modelStatusReplacementAlso named by DigiCheck before you swap
70002041PortServer TS 1DiscontinuedConnect EZ Mini (EZ01-MA00-GLB)EZ 4 TS (EZ04-TS00-GLB)Mini is DB9. EZ 4 TS keeps RJ45
70001805PortServer TS 1 MEIDiscontinuedConnect EZ Mini (EZ01-MA00-GLB)EZ 4 TS (EZ04-TS00-GLB)Both offer software-selectable RS-232/422/485
70001917PortServer TS 1 H MEIDiscontinuedConnect EZ Mini (EZ01-MA00-GLB)EZ 4 TS (EZ04-TS00-GLB)Extended-temperature unit: see temperature check below
70002043PortServer TS 2DiscontinuedConnect EZ 2 (EZ02-CA00-GLB)EZ 4 TS (EZ04-TS00-GLB)RJ45 serial pinout carries over
70001806PortServer TS 2 MEIDiscontinuedConnect EZ 2 (EZ02-CA00-GLB)EZ 4 TS (EZ04-TS00-GLB)RJ45 serial pinout carries over
70001992PortServer TS 2 P MEIDiscontinuedConnect EZ 4 PoE (EZ04-P000)EZ 2 (EZ02-CA00-GLB); EZ 4 TS (EZ04-TS00-GLB)Powered serial not confirmed on EZ
70001993PortServer TS 4 P MEIDiscontinuedConnect EZ 4 PoE (EZ04-P000)EZ 4 TS (EZ04-TS00-GLB); EZ 4 Wi-Fi (EZ04-WA00-GLB); EZ 4i (EZ04-IA00-EXT)Powered serial not confirmed on EZ
70002045PortServer TS 4NRND, still orderableConnect EZ 4 TS (EZ04-TS00-GLB)Not in the noticeRJ45 serial pinout carries over
70001807PortServer TS 4 MEINRND, still orderableConnect EZ 4 TS (EZ04-TS00-GLB)Not in the noticeSoftware-selectable RS-232/422/485
70001919PortServer TS 4 H MEINRND, still orderableConnect EZ 4 TS (EZ04-TS00-GLB)Not in the noticeWide-temperature users: see EZ 4i below
70001899PortServer TS 3 M MEINRND, still orderableConnect EZ 4 TS (EZ04-TS00-GLB)Not in the noticeInternal modem: see modem check below
70001851Digi One SPNRND, still orderableConnect EZ Mini (EZ01-MA00-GLB)Digi’s page also names EZ 2 and EZ 4DB9 on both: same pinout

The six Connect EZ models in play:

  • Connect EZ Mini (EZ01-MA00-GLB): one DB9 serial port, software-selectable RS-232/422/485, one Gigabit Ethernet port.
  • Connect EZ 2 (EZ02-CA00-GLB): two RJ45 serial ports, software-selectable RS-232/422/485, dual Gigabit Ethernet.
  • Connect EZ 4 TS (EZ04-TS00-GLB): four RJ45 serial ports, software-selectable RS-232/422/485, one Gigabit Ethernet port, an RS-232 console port, 12 VDC power supply included.
  • Connect EZ 4 PoE (EZ04-P000): four serial ports, dual Gigabit Ethernet, Wi-Fi, powered over Ethernet and supplied without accessories.
  • Connect EZ 4 Wi-Fi (EZ04-WA00-GLB): four serial ports, dual Gigabit Ethernet, Wi-Fi.
  • Connect EZ 4i (EZ04-IA00-EXT): four serial ports, Wi-Fi, -35 °C to +74 °C, Class I Division 2 as Digi states it.
Digi PortServer TS 4 serial device server

Will my cables and RealPort setup carry over?

Mostly. Digi states the Connect EZ 2 and EZ 4 use the same RJ45 serial pinout as PortServer TS, and RealPort carries over. The Connect EZ Mini has a DB9 connector, so a one-port unit on RJ45 cabling needs a cable or adapter change, or the EZ 4 TS instead.

Digi’s transition comparison sets out what stays the same:

  • Pinout: PortServer TS and the Connect EZ 2 and EZ 4 share the same RJ45 pinout. The Connect EZ Mini shares the DB9 pinout of the Digi One family.
  • Connectivity methods: RealPort COM port driver, TCP/UDP sockets, SSH, Telnet, Modbus TCP to RTU and SSL/TLS are all listed for PortServer TS and Connect EZ.
  • Management: web, CLI and SNMP remain. Digi Navigator replaces Digi Port Authority as the discovery and configuration tool.

The one real cabling change is the TS 1 to EZ Mini route. A TS 1 uses RJ45, the Mini uses DB9. If you want to keep the RJ45 cabling, choose the EZ 4 TS and leave three ports unused.

Serial modes improve on the way. The standard PortServer TS is RS-232 only. Every Connect EZ port is software-selectable between RS-232, RS-422 and RS-485.

Is the Connect EZ TS a like-for-like swap?

No. Digi’s own guidance states that the Connect EZ TS does not directly replace PortServer TS, although in most cases no major setup changes are needed. Check port count, operating temperature, powered-serial and modem use, and mounting before ordering.

Digi’s product pages describe the same footprint, RJ45 serial pinout and RealPort workflows. Digi’s FAQ is more careful. Run these checks:

  • Port count: the EZ 4 TS is four ports only. One- and two-port units go to the Mini or EZ 2.
  • Operating temperature: PortServer TS is stated at 0 °C to 60 °C. Every Connect EZ above except the EZ 4i is rated 0 °C to 40 °C. That is a real gap for a unit in a warm cabinet or plant room.
  • Hardened units: the TS H MEI family operates at -35 °C to +74 °C. For wide-temperature sites, look at the EZ 4i, stated at the same range.
  • PoE and powered serial: the TS P MEI models power a serial device over the RI or DTR pins. The EZ 4 PoE is powered over Ethernet, but Digi does not state powered serial for it. If you depend on it, talk to us first.
  • Modem units: the TS 3 M MEI has an internal v.90/v.92 modem. Digi’s replacement map names no Connect EZ model with a dial-up modem. Dial-up applications need a separate conversation.
  • Power and mounting: check the power supply and the wall-mount or DIN rail bracket you use today against the replacement.

What you gain: Digi TrustFence on the Connect EZ line, with encrypted connections, centralised authentication and VPN support, plus management through Digi Remote Manager.

Digi PortServer TS 1 serial device server

Should you make a last-time buy or migrate?

Make a last-time buy only if the installed base must stay on identical hardware until a planned project date and you can size spares now. Migrate if the unit sits on a network audit, needs current security features, or will outlive September 2027.

Buy stock before 30 January 2027Migrate to Connect EZ
Fits whenFixed project date, identical hardware requiredUnit will run beyond 2027 or faces an audit
GainNo change to cabling or setupCurrent product, TrustFence, central management
RiskNon-cancellable and non-returnable order; spares only buy timeTemperature, port and feature checks above

On the Connect EZ 4 TS, Digi lists a 5-year warranty on the base device and includes one year of LifeCycle Assurance, with 24×7 expert support and central management through Digi Remote Manager or Digi On-Prem Manager.

Digi lists an evaluation option for the EZ 4 TS in the notice (EZ04-TS00-CKIT). Ask us about test units before the January deadline. To size either route, send your part numbers and quantities and request a quote.

How do you plan the swap with minimal downtime?

  1. Inventory every unit by the part number on its label, and match each to the table.
  2. Check temperature, port count and any powered-serial or modem use.
  3. Confirm the cables and the RealPort COM port numbers in use.
  4. Stage and configure one unit on the bench with Digi Navigator.
  5. Pilot that unit on one site before rolling out.
  6. Swap site by site, keeping the old unit as a fallback until the application is confirmed.

Final thoughts

The deadline is fixed: 30 January 2027 for last-time-buy orders. For most models the map is simple, and the checks are temperature, port count and any feature beyond serial-over-IP.

Send us your PortServer TS part numbers and quantities and we will return the matching Connect EZ models. Start from the connectivity range or go straight to the Connect EZ 4 TS.

Frequently asked questions

Is the Digi PortServer TS end of life?

Seven PortServer TS models are discontinued under Digi notice PCN 261104-03. Five other models are marked not recommended for new designs but remain orderable. Last-time-buy orders close on 30 January 2027 and the last units ship on 30 September 2027.

What replaces the PortServer TS 4?

The Connect EZ 4 TS (EZ04-TS00-GLB) is the replacement for the PortServer TS 4, TS 4 MEI and TS 4 H MEI in Digi’s map. For the TS 4 P MEI, Digi’s notice names the EZ 4 PoE, EZ 4 TS, EZ 4 Wi-Fi and EZ 4i.

Will RealPort still work with the Connect EZ?

Yes. Digi lists the RealPort COM port driver for PortServer TS and for the Connect EZ family. Digi Navigator replaces Digi Port Authority for discovery and configuration.

Can I keep my existing serial cables?

On the Connect EZ 2 and EZ 4, yes: Digi states the RJ45 pinout is the same as PortServer TS. The Connect EZ Mini uses DB9, so a TS 1 moving to the Mini needs a cable or adapter change.

Can I order PortServer TS after 30 January 2027?

For the seven discontinued models, last-time-buy orders are accepted until 30 January 2027, are non-cancellable and non-returnable, and the last units ship on 30 September 2027. The five not-recommended models carry no dates in the notice.

Related

Digi Connect EZ 8 serial server
Digi Connect Sensor XRT-M remote monitor in its IP68 / NEMA 6P enclosure
Digi One IA industrial serial server with Modbus RTU to Modbus TCP conversion
Digi IX10 industrial cellular router with a serial port
Digi Connect EZ 4i industrial serial server
Digi Connect EZ 4 serial server with LTE and Wi-Fi

How Can We Help You?

We're here to assist and guide you with any enquiries you may have.

Simply complete the online form or reach out using the contact details provided below.