Guide

Serial Server Security: How to Protect Legacy Serial Devices

Legacy serial equipment rarely needs replacing, but the serial server in front of it often fails a security review. The Digi Connect EZ family adds enterprise authentication, a stateful firewall, encrypted connection options (TLS 1.2 and above, SSH, VPN), Digi TrustFence and central management at the connection point. Encryption is configured per connection, not on by default. Inventory your serial estate, then pilot one unit.

Digi Connect EZ 4i industrial serial server

The question usually arrives during a review: what is actually connected to our network? Someone points to the controllers, monitoring systems and meters running on RS-232, RS-422 and RS-485. They work. They have worked for years.

Once those devices sit behind an IP link, the position changes. Built-in authentication is limited, serial traffic can cross the network unencrypted, and equipment that was isolated gains new access paths. The fix is not replacement. It is securing the connection layer around the equipment.

This guide gives utilities, manufacturers, healthcare IT teams and integrators an audit checklist, a feature-to-finding table and a model guide. For the wider range, see our connectivity products. For the Connect EZ TS transition, read our post on modernising serial connectivity with the Connect EZ TS.

Why do legacy serial servers fail modern security reviews?

Legacy serial devices were built to be dependable, not to defend themselves. The serial servers around them often lack secure boot, modern encryption and central management, and review expectations have risen. The equipment is not the problem. The connection layer needs to catch up.

Digi names four risks once serial equipment joins an IP network:

  • Limited built-in authentication. You must control which users and systems reach each device.
  • Unencrypted traffic. Serial data sent over IP without encryption can be intercepted.
  • More access paths. Connectivity opens routes to previously isolated equipment.
  • Inconsistent upkeep. Distributed equipment is harder to monitor, configure and update without central tools.

Management is where the pain shows: logging in to each unit one at a time, checking firmware by hand, no single view. Digi also states that units running continuously for years can suffer memory write degradation, which can cause data loss without obvious warning signs.

Digi Connect EZ Mini single-port serial server

What do UK laws and frameworks ask of a serial estate?

UK laws and frameworks ask for access control, protected data, secure configuration, monitoring and update management, in general terms. The NIS Regulations and the CAF set outcomes, not rules for particular devices, and no single device makes an organisation compliant. A serial server is one control within a wider programme.

The table describes four sources in general terms and lists the evidence a reviewer may ask for at the serial layer.

SourceIn general termsEvidence at the serial layer
NIS Regulations 2018Apply to operators of essential services, such as larger organisations in energy, transport, drinking water, healthcare and digital infrastructure, and to some digital service providers. Scope depends on sector and size, or on designation by the regulator. Each sector has a competent authority that oversees compliance.Which serial servers support the essential service, who can reach them, and how they are patched.
NCSC Cyber Assessment Framework (CAF)Version 4.0 has four objectives: managing security risk, protecting against cyber attack, detecting cyber security events, and minimising the impact of incidents.B: identity and access control, data security and system security. C: evidence you can detect problems, such as logs and monitoring. D: a way to recover.
Cyber EssentialsFive technical controls: firewalls, secure configuration, security update management, user access control and malware protection.Firewall rules, a documented configuration, current firmware and authenticated administration.
IEC 62443An international series of standards for securing industrial automation and control systems.Serial servers sit in a defined zone, with only approved connections (conduits) to and from it.

Many NIS regulators use the NCSC Cyber Assessment Framework to judge how well an operator manages cyber risk. Your own regulator’s guidance sets the exact expectation. The CAF is assessed against the essential service an organisation runs, so a reviewer will want to know which systems support that service.

For Cyber Essentials, the organisation sets and describes the scope of its certificate, and exclusions need a reason. Check whether the serial servers fall inside that scope. IEC 62443 is an international series of standards rather than UK law, though a contract or a regulator may ask for it.

Digi states that Connect EZ security features support broader access-control and compliance efforts, but that no individual device guarantees regulatory compliance.

How do you audit a legacy serial estate before you change anything?

Start with an inventory: serial interfaces, protocols, application dependencies and authorised network destinations. Then check who can reach each device, whether traffic is encrypted, what firmware each unit runs and how it is managed. Test the fix on one device before you migrate more.

Digi sets out five practices. Work through them in order:

  1. Inventory. Document serial interfaces (RS-232, RS-422 or RS-485), protocols, application dependencies and authorised network destinations.
  2. Access. Use authentication and firewall rules to limit connections to authorised users, systems and services.
  3. Segmentation. Keep serial-connected equipment apart from unrelated traffic, and restrict access to management interfaces.
  4. Maintained configuration. Review firmware, document approved security settings and verify application compatibility before changing several devices at once.
  5. Encryption. Configure TLS, SSH or an appropriate VPN when serial data crosses an IP network.

The IEC 62443 series describes a similar idea: divide the network into zones, with controlled connections between them.

Then pilot with one device. A pilot shows how your applications, serial settings and recovery behaviour respond before you migrate more. Modernising means updating the layer that joins the equipment to the network, not replacing the equipment. Connect EZ supports serial tunnelling, TCP/UDP connections and Digi RealPort COM and TTY redirection, so compatible applications keep working through familiar interfaces.

Digi Connect EZ 8 serial server

Does serial traffic need encryption, and is it on by default?

Yes, serial data sent over IP without encryption can be intercepted. Digi Connect EZ supports TLS 1.2 and above, SSH, encrypted TCP and VPN options, but encryption depends on how each connection is configured. It is not on by default, so configure it for every application.

The table maps common audit findings to the feature Digi states for the family.

Audit findingConnect EZ feature, as Digi states it
Weak or shared admin loginsRADIUS, TACACS+, LDAP and digital certificates tie access to your identity management
Serial data in clear over IPTLS 1.2 and above, SSH, encrypted TCP; IPsec (IKEv1, IKEv2) and OpenVPN tunnels, with AES up to 256-bit in IPsec
Open paths to old equipmentStateful firewall, IP filtering, custom firewall rules, MAC address filtering, VLAN support
No trust in the deviceDigi TrustFence (see the next section)
Unknown firmware and settingsDigi Remote Manager (cloud) or Digi On-Prem Manager (local); Digi Navigator for local discovery
No activity recordEvent logging with syslog and an SMTP client; SNMP v2 and v3 (v3 user installed and managed)

Feature availability varies by model, so confirm details in the datasheet for your model. For the short answer, see our FAQ: Are serial servers secure?

What is secure boot, and why can you not add it later?

Secure boot makes sure only trusted firmware runs on a device. Digi states it is now a baseline requirement in many environments and has to be built into the hardware, so older platforms cannot gain it later. Digi TrustFence builds device protection into the unit itself.

Digi describes TrustFence as securing the device, not just the data passing through it, with support for encrypted communications and device authentication. On the Connect EZ Mini, 2 and 4 family, Digi’s specification lists secure boot. The Connect EZ TS, 8, 16 and 32 carry built-in Digi TrustFence.

TrustFence protects the Connect EZ itself, not the serial equipment behind it. Regular firmware updates keep protections current, so review release notes and test updates against your applications. Replacing an older Digi serial server? Our PortServer TS replacement guide covers that decision.

Digi Connect EZ 16 rack-mount serial server

How do you manage and evidence many serial servers centrally?

Use central management so you see every serial server in one place. Digi Remote Manager is cloud based. Digi On-Prem Manager is hosted locally for organisations that restrict cloud management, including air-gapped sites. One year of Digi LifeCycle Assurance is included with Connect EZ.

  • Digi Remote Manager: cloud-based monitoring, configuration and troubleshooting.
  • Digi On-Prem Manager: device management hosted on your own infrastructure.
  • Digi Navigator: local discovery and configuration.
  • Built-in Python: local scripting on the device.

Digi states that Remote Manager keeps a record of configuration changes, firmware update history, access events and device health.

Digi also states one year of LifeCycle Assurance at purchase (24×7 expert support and central management), a 5-year warranty on the base device and a 3-year warranty on the CORE LTE modem.

For an independent path to the equipment, see our out-of-band management guide. Digi states that a Connect EZ with a CORE LTE modem and Digi SureLink gives a separate cellular path with automatic failover. The EZ 2, 4, 4i, 8, 16 and 32 take the modem. The EZ Mini and EZ TS do not.

Which Digi Connect EZ model fits which site?

Pick by port count, environment and connectivity. The Connect EZ Mini, 2 and 4 suit one to four serial devices, with LTE as an option on the 2 and 4, and Wi-Fi on the 4. The EZ 4i adds a -35 °C to 74 °C range, and Digi lists it for Class I, Division 2. The EZ 8, 16 and 32 are 1U rack units, with dual power on 16 and 32.

ModelSerial portsNetwork and radioEnvironment and power
Connect EZ Mini1, software-selectable RS-232/422/4851 Ethernet0 °C to 40 °C; 9 to 30 VDC
Connect EZ 22, software-selectableDual Ethernet; optional LTE0 °C to 40 °C
Connect EZ 44, software-selectableDual Ethernet; Wi-Fi; optional LTE0 °C to 40 °C
Connect EZ 4i4, software-selectableDual Ethernet; Wi-Fi; optional LTE-35 °C to 74 °C (-35 °C to 70 °C with CORE modem); Class I, Division 2
Connect EZ 4 TS4, software-selectable1 Ethernet; no Wi-Fi or LTE0 °C to 40 °C; slim, panel-friendly
Connect EZ 88 RS-232; MEI model RS-232/422/485Dual Ethernet; dual SFP+; CORE LTE socket0 °C to 50 °C; 1U rack
Connect EZ 16 and 3216 or 32 RS-232; MEI models RS-232/422/485Dual Ethernet; dual SFP+; CORE LTE socket0 °C to 50 °C; 1U rack; single or dual AC, or dual 48 VDC

All values are as Digi states them. Choose by site:

  • Cold or vibrating sites: the Connect EZ 4i, which Digi lists with IEC 60068-2-64 and 60068-2-27 shock and vibration ratings.
  • Dense racks: the EZ 8, or the Connect EZ 16 and 32. Digi states the dual AC and dual DC supplies are field-replaceable, so a supply can be swapped without downtime.
  • Replacing an existing Digi TS server: the EZ 4 TS, or the 8 TS for eight ports.

Final thoughts

You do not have to replace equipment that works. Secure the connection layer: inventory, authenticate, restrict, encrypt, keep firmware current and manage centrally. Pilot one unit, then scale.

Send us your site list and serial inventory, and we will match the Connect EZ model to each location. Start with the connectivity products range and request a quote through the product pages.

Frequently asked questions

Are serial servers secure?

They can be, if you configure them. Serial data sent over IP without encryption can be intercepted, so use encrypted connections, authentication, firewall rules and network segmentation. Digi Connect EZ supports TLS 1.2 and above, SSH, VPN options and enterprise authentication. Protection depends on how you configure each connection.

Do I need to replace legacy serial equipment to secure it?

No. A serial device server adds network connectivity and security to the equipment you already have. Digi Connect EZ supports serial tunnelling, TCP/UDP connections and RealPort COM and TTY redirection. Test application compatibility and serial settings on a pilot unit first.

Is serial data encrypted by default on Digi Connect EZ?

No. Supported options include TLS 1.2 and above, SSH, encrypted TCP and VPN configurations, but encryption depends on the connection method and its configuration. Configure it for each application. Feature availability varies by model, so confirm details in the datasheet.

Does a Digi Connect EZ make my site compliant with NIS, the CAF, Cyber Essentials or IEC 62443?

No. No single device does. Digi states that Connect EZ security features support broader access-control and compliance efforts, but no individual device guarantees regulatory compliance. The requirements fall on the organisation, and a serial server is one control within its wider programme.

Can I manage serial servers without cloud access?

Yes. Digi On-Prem Manager is a locally hosted management option for environments that restrict cloud management, including air-gapped sites. Digi describes it as device management that runs on your own infrastructure, as an alternative to Digi Remote Manager.

Related

Digi Connect EZ 8 serial server
Digi Connect Sensor XRT-M remote monitor in its IP68 / NEMA 6P enclosure
Digi One IA industrial serial server with Modbus RTU to Modbus TCP conversion
Digi IX10 industrial cellular router with a serial port
Digi Connect EZ 4 serial server with LTE and Wi-Fi
Digi Connect EZ serial device server family

How Can We Help You?