At a glance
- Connectivity is the parent category for 220 products, split across 16 sub-categories: routers, gateways, switches, bridges, device servers, KVM, network appliances and a few accessories.
- The three router categories overlap: rugged routers (88) is the overview, and cellular routers (80) and industrial routers (60) are narrower views of the same products. The sub-category counts therefore add up to more than 220.
- Start from what you are connecting: a site to a mobile network, equipment to a wired network, serial or USB devices to IP, or several computers to one console.
- Many product descriptions state IP30 housings and metal cases, and some state DIN rail mounting. A small number state hazardous-area wording. The marking and certificate of the exact model must match your site’s zone.
What is in the Connectivity category?
Connectivity covers the hardware that joins equipment to a network or to other equipment: routers that bring in a cellular or wired uplink, gateways that translate between protocols, switches that spread a wired connection, bridges that replace a cable with Wi-Fi, device servers that put serial and USB devices on the network, and KVM units that share one keyboard, mouse and display between computers.
The products are intended for cabinets, plant rooms, vehicles, ships, racks and outdoor sites rather than office closets. The product text for the category mentions aluminium and metal cases, wide temperature ranges and DIN rail mounting on many products, but the figures differ by model. Treat the numbers on this page as pointers and the datasheet as the specification.
How do the sub-categories compare?
| Sub-category | Products | What it covers | Go here when |
|---|---|---|---|
| Rugged routers | 88 | All router types: wired, 4G, 5G, vehicle, rail and outdoor | You want the overview before narrowing down |
| Cellular routers | 80 | 4G and 5G routers with SIM and eSIM options | The uplink is a mobile network |
| Industrial routers | 60 | Routers chosen for wired ports, power input, serial and mounting | You are wiring a cabinet or control panel |
| Outdoor routers | 6 | Routers described for outdoor use | The unit mounts outside, not in a cabinet |
| Embedded routers | 2 | Routers for building into other equipment | You are an integrator designing a product |
| Industrial gateways | 30 | LoRaWAN, edge computing, IoT and maritime gateways | Data must be translated or processed on site |
| Industrial modems | 6 | Cellular modems for separate equipment | A host already routes and only needs a cellular link |
| Network switches | 13 | Managed and unmanaged switches, some with PoE | You need more wired ports |
| Network appliances | 24 | Rackmount and fanless platforms, plug-in network modules | You are building a firewall or network function |
| Serial connectivity | 14 | Serial device servers | Legacy RS-232, RS-422 or RS-485 equipment must join an IP network |
| USB connectivity | 7 | USB over Ethernet and Wi-Fi device servers | A USB device must sit away from its computer |
| KVM | 25 | KVM switches and extenders | Several computers share one keyboard, mouse and display |
| Console servers | 3 | Serial console access for network equipment | You manage routers and switches remotely |
| Wireless bridges | 6 | Ethernet to Wi-Fi bridges | A cable cannot be run to the equipment |
| Access points | 4 | Wi-Fi access points | You are adding wireless coverage |
| Antennas | 1 | A 5G antenna | You are completing a cellular installation |
What to check on the datasheet
- The uplink: wired, 4G, 5G or Wi-Fi, and the generation and band support if it is cellular.
- The number and speed of Ethernet ports, and whether any supply Power over Ethernet.
- Serial interfaces, and whether they are RS-232 only or selectable between RS-232, RS-422 and RS-485.
- Power input range, and whether it suits a vehicle, a 24 V cabinet or a mains supply.
- Housing, mounting and any stated IP rating, since IP30 and IP67 are very different levels of protection.
- Operating temperature, as stated by the maker, against the coldest and hottest point on your site.
- Any hazardous-area marking. The marking and certificate of the exact model must match the site’s zone.
How do you choose a connectivity category?
- Name the job: uplink, switching, protocol translation, serial or USB sharing, or console sharing.
- If the uplink is cellular, go to cellular routers. If the choice is mainly wiring, go to industrial routers. If you are undecided, start with rugged routers.
- If the equipment speaks serial, Modbus or LoRaWAN, look at gateways and serial connectivity.
- Count the wired ports you need and add switches if the router has too few.
- Match the housing and temperature range to where the unit will sit.
- Check the standards you are asked to meet in the standards cheat sheet.
What to tell us for a quote
Send the type of uplink, the number of devices to connect, the interfaces they use, the power supply available, the mounting method and the site conditions. For cellular products, name the country and the network you will use. If any part of the site is a classified hazardous area, say so at the start.
Related guides and ranges
- Rugged routers
- Cellular routers
- Industrial routers
- Industrial gateways
- Network switches
- IP ratings explained
- Standards cheat sheet
- ATEX tablets
- Rail and transport
Frequently asked questions
What is the difference between a router and a gateway?
A router moves traffic between networks. In this category a gateway usually also translates between protocols or runs software on site, for example LoRaWAN, serial or building automation protocols. The industrial gateways page lists the types.
Why do the router categories overlap?
Rugged routers is the overview of all router types. Cellular routers and industrial routers are two ways of looking at the same products, by uplink and by wiring. A product can sit in all three.
Do all connectivity products have an IP rating?
No. Many descriptions state IP30, a few state higher ratings such as IP64, IP66 or IP67, and some state none. The IP ratings guide explains how to read them.
Are any connectivity products rated for hazardous areas?
A few product descriptions carry hazardous-area wording, listed as Class I, Division 2, with ATEX wording on two and an IECEx test report reference on one. Class I, Division 2 is a North American classification, not a UK or EU zone marking. A DSEAR-zoned site needs equipment marked and certified for that zone (UKEX, ATEX or IECEx). Read how to read an Ex marking and confirm that the marking and certificate of the exact model match your zone.
Can I connect serial equipment to a cellular network?
Yes. Several routers and gateways have serial ports, and serial device servers convert serial to IP. See serial connectivity and cellular routers.