A remote pumping station, a plant room or a meter cabinet has run for years on one analogue line. The autodialler raises the alarm. The SCADA master dials in to poll. Nobody has touched the modem in a decade.
Openreach’s date for switching off the PSTN is 31 January 2027. When the line goes, the equipment keeps working and nothing can reach it. The fix is to move the data path to IP and keep the asset.
This guide is for engineers and facilities or IT managers with telemetry, SCADA dial-up links, meters and plant controllers. It does not cover lift lines, telecare or alarm monitoring signalling. Those go to their own suppliers. For the products that carry serial data over IP, see our connectivity products.
What happens to dial-up equipment when the PSTN is switched off?
Equipment that dials out or answers calls over a traditional phone line loses that line when it is withdrawn. The equipment is not obsolete. Only the path to it is. Move that path to IP or cellular, and check the equipment can work without a modem.
Openreach confirmed on 24 September 2026 that the 31 January 2027 date is unchanged. GOV.UK says all users of the Openreach PSTN need to be migrated to new services by that date. It is Openreach’s network programme date.
Other networks, such as KCOM in Hull and Virgin Media, run their own timetables. Ask your provider which network carries each of your lines.
Openreach reported in October 2026 that around one million copper lines remain, about 300,000 at business premises.
Lines still on the old network on the day may be moved by their provider to EVAc, a temporary, limited, last-resort service from Openreach. It is voice only and cannot be ordered in advance. Do not rely on it for alarm signalling or data. Openreach says ISDN services not migrated by January 2027 will be ceased. Treat it as a safety net for voice calls, not a plan for telemetry.
Which equipment dials out over a phone line?
Openreach lists alarms, CCTV, payment terminals, telecare, door entry, lift phones and auto-diallers, and industrial telemetry. Who fixes each differs. We help with telemetry and industrial serial equipment. Lift, alarm and telecare lines go to their own supplier.
Ofcom has told providers that alarms, telemetry and monitoring equipment may need to be reconfigured or replaced, because some PSTN characteristics, such as line powering, may not be carried over to all-IP services. Dial-up SCADA links, remote terminal units and meters are common examples of telemetry on copper. Openreach does not name them, so treat them as our examples.
| Equipment | Who fixes it |
|---|---|
| Telemetry outstation, RTU, PLC, SCADA remote | This guide: serial server or cellular router, at both ends |
| Meters with a serial port | This guide. A built-in modem with no port: ask the meter maker |
| Building and plant controllers | This guide |
| Payment terminals | The terminal or acquirer supplier first |
| Alarm panels, lift emergency lines, telecare | Your maintainer or supplier |
Lift alarm lines are a safety system with their own requirements. Speak to your lift maintainer before anything changes. We do not position Digi products for lift, alarm or telecare signalling.
The DSIT PSTN charter puts vulnerable and telecare users first. The DSIT critical national infrastructure (CNI) charter covers assets and services where loss of PSTN or ISDN connectivity could result in loss of life, and asks owners to engage with their provider. Ofcom has asked providers to put migration solutions in place for CNI users in good time.
Will your serial equipment work over IP?
Often yes, but check the modem first. If the host talks to the equipment in a serial protocol such as Modbus and the modem is only the carrier, replace both ends with IP. If the equipment sends modem commands or has a modem built in, it needs more.
Three cases cover most sites:
- Case A, external modem on a serial port. The equipment speaks a serial protocol and the modem is a separate box. Remove the modem. A serial server carries the same serial data over IP. This is the common telemetry case. Where the protocol is Modbus, the Digi One IA and IAP also convert Modbus RTU and ASCII to Modbus/TCP.
- Case B, equipment sends modem commands. Some equipment dials by sending commands to the modem and waits for replies. A plain serial server will not answer them. Digi states modem emulation for the Digi One SP IA and the Digi One SP, “allowing equipment designed for modem access to communicate transparently across the Ethernet”. Digi does not state it for the Connect EZ, Digi One IA, Digi One IAP or IX routers, so confirm with us before ordering for this case.
- Case C, modem built into the equipment. An RJ-11 jack and no serial port means nothing to convert. Ask the equipment maker for an IP or cellular upgrade or a replacement communications module.
Plan three more points. Both ends change: the master’s modem bank or dial-in server moves to IP at the same time as the outstation. Polling built around short calls needs its timing and timeouts reviewed over IP. A serial-to-IP link puts the equipment on a network, so use a private APN or a VPN.

Which replacement fits: serial to cellular, serial to Ethernet or a cellular router?
No wired IP line on site: use a Connect EZ LTE serial server or a Digi IX cellular router. A wired IP line exists: use a Digi One IA or IAP. Equipment that sends modem commands: the Digi One SP IA, with a cellular router where there is no wired line.
| Product | Serial port | Network side | Operating temperature |
|---|---|---|---|
| Connect EZ 2 LTE (EZ02-CAG4-GLB) | 2 x RS-232/422/485 | LTE Cat 4, dual SIM | 0 to 40 °C |
| Connect EZ 4 LTE (EZ04-WAG4-GLB) | 4 x RS-232/422/485 | LTE Cat 4, Wi-Fi, dual SIM | 0 to 40 °C |
| Connect EZ 4i LTE (EZ04-IAG4-EXT) | 4 x RS-232/422/485 | LTE Cat 4, Wi-Fi, dual SIM | -35 °C to 70 °C with the Digi CORE LTE modem fitted |
| Digi One IA (70001862) | 1 x RS-232/422/485 | Ethernet | 0 to 60 °C |
| Digi One IAP (70001777) | 1 x RS-232/422/485 | Ethernet, 802.3af PoE | 0 to 60 °C |
| Digi One SP IA (70001999) | 1 x RS-232/422/485 | Ethernet, modem emulation | 10 to 45 °C |
| Digi IX10-00G4 | 1 x RS-232/485 | LTE Cat 4 Global, dual SIM | -40 to 70 °C |
| Digi IX25-5A-1G | 1 x RS-232/485 | 5G, LTE Cat 19 fallback | -40 to 75 °C |
| Digi IX30-0EG4 | 1 x RS-232/422/485 | LTE Cat 4 Global, dual SIM | -34 to 74 °C |
| Digi IX40-05 | 1 x RS-232/422/485 | 5G, LTE-Advanced Pro Cat 19 | -40 to 75 °C |
Selection rules:
- Below 0 °C. The Connect EZ 2 and 4 LTE run from 0 to 40 °C. An outdoor cabinet that goes colder needs the EZ 4i or an IX router.
- One device, wired IP line. The Digi One IA is the direct fit. The IAP adds power over Ethernet, with fail-over to 9 to 30 VDC.
- Cellular routers. Each IX router has one serial port, of the type shown. Confirm with us how the port is used for your equipment before you order.
- Cellular bands. The Connect EZ LTE models and IX10 and IX30 are Global variants as Digi states. Confirm coverage at the site with your SIM provider.
Digi states Class I, Division 2 for the Connect EZ 4i and the Digi One IAP.
What about the PortServer TS 3 M MEI with the internal modem?
The PortServer TS 3 M MEI (70001899) has an internal V.90/V.92 modem on an RJ-11 line, so it can dial in or out. The phone line is the part the switch-off removes. Digi recommends the Connect EZ 4 TS for new designs and does not list an internal modem on it.
An existing unit still works as a serial server over Ethernet. Move its remote access to IP, through your Ethernet network or a cellular router. PPP stays on the TS 3 M MEI. If you refresh it with the EZ 4 TS, plan the remote access route first, because Digi lists no modem there.
Digi’s last-time-buy date for the PortServer TS range, 30 January 2027, is a separate event one day before the PSTN date. The PortServer TS replacement guide has the part-number map.

How do you keep equipment running through a power cut?
Power fed down the old copper line may not carry over to the new path, so the replacement needs its own power and backup. Ofcom’s one-hour rule covers access to emergency calls only. It does not keep an outstation running. Size battery or UPS hold-up for the modem path and the equipment together.
Ofcom’s rule requires providers to have at least one solution, such as a battery back-up unit, that lets landline-dependent customers reach emergency organisations for at least one hour in a power cut. That is access to emergency calls. It is not a duty to keep an alarm, a meter or a telemetry unit working.
Size the backup from three numbers: the load of the modem path and the equipment, the hours of cover you need, and the battery type. The Connect EZ units, Digi One IA, IAP and SP IA take 9 to 30 VDC, which suits battery-backed supplies. The IAP can also run from power over Ethernet. The Connect EZ and IX routers carry dual SIM slots, so a second network is straightforward to design in.
Should the replacement path use LTE or 5G?
LTE is the baseline. The Connect EZ LTE models list 3G and 2G fallback, but Ofcom confirms all four UK networks have now switched off 3G, and 2G switch-offs are due to start from 2029. Design on 4G. The IX25-5A-1G and IX40-05 add 5G where a site wants it.
How do you plan the move before the switch-off date?
Work through eight steps:
- List every line: number, equipment, location and who owns the equipment.
- Sort with the table above. Take lift, alarm and telecare lines to their maintainers.
- For each telemetry or SCADA unit, find the interface: case A, B or C.
- Check power and temperature at the cabinet.
- Pick the product from the decision table.
- Change both ends together.
- Pilot one unit at one site. Confirm polling and alarm delivery over IP.
- Roll out site by site. Keep the old line until the new path has carried real traffic, and ask your provider when each line is due to move.
Openreach advises businesses to audit their analogue services and work with their provider on a migration plan now. Confirm stock lead times with us before you order, as several steps depend on delivery.
Final thoughts
Openreach says the switch-off date is unchanged. The equipment can usually stay. The work is to take the modem out of the path and confirm the equipment speaks IP. Contact us with your equipment list and the serial interface of each unit, and we will match each one to a product in the table.
Frequently asked questions
Will my dial-up modem still work after the PSTN switch off?
Not over the old phone line. Openreach switches off the PSTN on 31 January 2027. The serial equipment behind the modem can usually stay if you move the data path to IP or cellular.
Can a 4G router or serial server replace a dial-up modem?
Where the equipment speaks a serial protocol, yes: a serial server carries the data over IP. Equipment that sends modem commands needs modem emulation, which Digi states for the Digi One SP IA and Digi One SP. Confirm with us first.
Do I have to replace my RTU, meter or outstation?
Usually not, if it has a serial port. If the modem is built in with no serial port, ask the equipment maker for an IP or cellular upgrade.
What about lift lines, alarm panels and telecare?
Speak to your lift or alarm maintainer or telecare supplier. These are safety systems with their own requirements, and we do not position Digi products for them.
What happens to my equipment in a power cut?
Power fed down the old copper line may not carry over to the new path, so the replacement needs its own power and backup. Ofcom’s one-hour rule covers access to emergency calls only. Specify battery or UPS hold-up, and use dual SIM where a second network helps.