A tank that runs dry stops a process. A tank that overfills creates a clean-up. When the only way to know the level is a person on site, both happen between visits. Remote tank monitoring closes that gap: a level sensor, a cellular gateway and a screen that shows the reading wherever you are.
The Digi Connect Sensor XRT-M is a rugged, battery-powered cellular IoT gateway for exactly this job. It connects to field sensors over analog, digital and Modbus interfaces and sends the data to Digi Axess or to any MQTT broker. Digi states it removes the cost and complexity of wiring infrastructure to remote monitoring points, and reduces truck rolls, manual reads and missed compliance events.
This guide covers how the XRT-M reads a tank, which of the three part numbers fits which site, and what to check before you specify it in the UK. Browse the wider range of cellular and serial connectivity products if your site needs more than tank data.
What is remote tank monitoring over cellular?
Remote tank monitoring is a level sensor on the tank, wired to a gateway that sends readings over a cellular network to a platform you check on screen. It replaces manual dips and site visits with scheduled readings and alerts. The gateway can run on battery where no mains or fixed network exists.
Three parts make up the system:
- Sensor: a level transmitter on the tank (ultrasonic, radar or hydrostatic) with a 4-20 mA or Modbus output.
- Gateway: the XRT-M, which reads the sensor and sends the data over LTE-M or NB-IoT.
- Platform: Digi Axess, or your own MQTT broker, where readings, alerts and reports live.
Digi lists the sectors that use the XRT-M: water and wastewater, oil and gas (pipeline and tank monitoring), industrial gas distribution, mining, agriculture, green stormwater infrastructure and environmental regulatory compliance. The common factor is a point of measurement that is far from power, far from a network and expensive to visit.

Why do battery power and LTE-M suit remote tanks?
Tanks are often where mains power and wired networks are not. The XRT-M runs on dual lithium thionyl chloride batteries, which Digi rates at about five years at two reads and transmits a day. It uses LTE-M and NB-IoT, low-power cellular modes designed for small, infrequent messages.
A level reading is a few bytes. It does not need a broadband link or a mains socket. The XRT-M is built around that fact:
- Battery: dual 7.2 V, 12 Ah lithium thionyl chloride cells, non-rechargeable and replaceable.
- Battery life: about five years at two reads and transmits per day. That figure is Digi’s, at that reporting rate. More frequent reporting shortens it.
- Sleeping draw: 115 microwatts. Peak transmit draw is 14.4 W.
- Storage: less than 1% battery discharge per year at 30 °C.
- External power: 9 to 30 VDC where a supply exists. The M210 runs on mains, battery or both together.
- SIM: one standard (2FF) slot.
The power figures exclude the draw of any external sensor you power from the XRT-M, so size the battery plan with the sensor in mind.
How does the XRT-M read a tank level?
It reads the level sensor you already use. Four analog inputs configure as 4-20 mA current loop or 0-10 VDC, with a 12-bit converter. It also reads up to four Modbus RTU or ASCII sensors and counts pulses up to 2 kHz. Six power outputs can power the sensor itself.
The XRT-M is a gateway, not a level sensor. You fit a level transmitter with a 4-20 mA or Modbus output, and the XRT-M reads it. Digi calls this a “bring your own sensor” approach. You keep the sensor type you trust and standardise how the data is collected and delivered.
| Input | What the XRT-M supports | Tank use |
|---|---|---|
| Analog (4 inputs) | 4-20 mA or 0-10 VDC, 12-bit | Level transmitter on a bulk tank |
| Modbus | RTU and ASCII, up to 4 sensors | Level or process sensor with a serial output |
| Digital / pulse | 1 input, up to 2 kHz | Flow meter on the fill line, float switch alarm |
| Sensor power | 6 outputs: 3.3, 5, 15 or 24 VDC, up to 200 mA | Powers the level sensor directly |
Two details matter at a tank:
- Sensor power on board. Each analog input has a user-enabled power output, so a loop-powered or low-power sensor needs no separate supply.
- Wake on alarm. The digital input wakes the unit from sleep on a rising or falling edge. A high-level float switch can trigger a report without waiting for the next scheduled reading.
Modbus is the common language of industrial sensors. Our guide to Modbus RTU and ASCII explains how the protocol works. Sensors are configured in Digi Axess.
Which XRT-M model suits which tank site?
Use the M210 for a tank outdoors: it has the IP68 / NEMA 6P enclosure and includes batteries. Use the M210-N where mains is available or batteries are supplied separately. Use the M110 for an enclosure or cabinet with mains power: it is a DIN rail module rated IP30.
All three part numbers share the same cellular, input and platform specification. They differ in enclosure, power and batteries.
| Item | CSENSE-M110 | CSENSE-M210 | CSENSE-M210-N |
|---|---|---|---|
| Form | DIN rail module | NEMA enclosure | NEMA enclosure |
| Enclosure rating | IP30 | IP68 / NEMA 6P | IP68 / NEMA 6P |
| Power | 9 to 30 VDC | Mains, battery or both | 9 to 30 VDC, or batteries bought separately |
| Batteries | None | Included | Not included |
| Antenna | SMA connector | Internal | Internal |
| Size (L x W x H) | 149.9 x 76.2 x 22.2 mm | 194.97 x 157.05 x 120.78 mm, excluding glands | Same as M210 |
| Weight | 0.20 kg | 1.36 kg | 1.36 kg |
| Hazardous locations | No claim | UL Class I Division 2 | UL Class I Division 2 |
- The Digi Connect Sensor XRT-M with NEMA enclosure (CSENSE-M210) is the outdoor, off-grid choice. Batteries and antenna are included.
- The CSENSE-M210-N is the same enclosure without batteries. Choose it where a 9 to 30 VDC supply is on site.
- The Digi Connect Sensor XRT-M DIN rail module (CSENSE-M110) suits a control cabinet with mains, and needs its own enclosure and antenna.
Digi lists magnetic mount and pole mount accessories for the XRT-M, plus replacement batteries. All models carry a three-year warranty.
How do readings reach you? Digi Axess and MQTT
Readings go to Digi Axess, Digi’s cloud platform, to your own MQTT broker, or both at once. Axess gives dashboards, map views, alerts, alarms and reports on the web and in an iOS and Android app. No local PC or proprietary controller is needed.
Digi Axess is the cloud platform built for the XRT-M. It stores device health and sensor data, and it sends alerts and alarms by text message, cloud and email. Reports are tailored to what you track.
- Direct-to-broker MQTT. The XRT-M publishes to any MQTT broker, with or without Axess. It fits an existing SCADA or IIoT platform without a second system.
- Both at once. The same reading goes to Axess and your broker. Digi describes the product as cloud-agnostic.
- Fast setup. Digi designs setup to take under 10 minutes, using preloaded configurations and zero-touch provisioning.
- Location. GPS is not part of the XRT-M specification. Location shows at asset level in Axess map and aerial views, tied to device registration. A tank does not move, so this is enough.

Remote tank monitoring in the UK: what to check
The XRT-M is designed for water and wastewater, fuel and gas storage, mining, agriculture and environmental sites. In the UK the sites that fit are bulk fuel or oil storage on a business site, water reservoirs and treatment sites, chemical dosing tanks, agricultural water or fuel tanks, and unmanned remote locations.
Four checks keep a UK deployment clean:
- Network. The XRT-M supports global LTE-M and NB-IoT bands, including B3, B8 and B20. Coverage depends on the location, so confirm LTE-M or NB-IoT coverage at the tank with your SIM provider before you specify.
- Antenna position. Cellular signal is weak in buried chambers and inside reinforced concrete. The M110 in a cabinet can use an SMA antenna mounted where the signal is. The M210 has an internal antenna, so check signal at the mounting point.
- Oil storage rules. In England, above-ground oil containers over 200 litres fall under the Control of Pollution (Oil Storage) (England) Regulations 2001, enforced by the Environment Agency. Monitoring gives an early view of loss. It sits alongside bunding, not in place of it.
- Your regulator. If the tank falls under sector regulation, confirm the reporting requirement with that regulator before you design the data flow.
The sensor, the gateway and the signal need to be chosen together. A good level transmitter on a tank with no signal still leaves you driving to site.
What IP68 / NEMA 6P and Class I Division 2 mean for a tank site
The M210 enclosure is rated IP68 / NEMA 6P, which Digi describes as protection against complete submersion. The M210 carries UL Class I Division 2 with the corresponding Canadian certifications, EN IEC 60079-0:2018 and EN 60079-15:2010. Operating range is -35 °C to 70 °C.
Tank sites are wet, dusty and exposed. The enclosure ratings are the baseline, not an upgrade:
- IP68 / NEMA 6P (M210 and M210-N): dust-tight and protected against complete submersion. A flooded chamber or a washdown does not stop the unit.
- IP30 (M110): a DIN rail module for use inside a cabinet or enclosure.
- Temperature: -35 °C to 70 °C operating, -40 °C to 85 °C storage.
For hazardous locations, Digi states that the M210 enclosure model carries UL Class I Division 2 certification with corresponding Canadian certifications, EN IEC 60079-0:2018 and EN 60079-15:2010. Digi describes it as suitable for Class I and II Division 2 and Class III hazardous locations, against UL 121201 and CSA C22.2 No. 213-17. The M110 is an IP30 DIN rail module. Digi makes no hazardous-area claim for it.
Other approvals Digi lists include UL/IEC/EN 62368-1, FCC Part 15 Class B, EN 301 489-1, EN 301 489-17 and EN 55035. If your tank site sits in a classified area, send us the zone classification and we will confirm the right model.
Final thoughts
A tank without power or a wired network can still report its level. The sensor, the gateway and the signal need to be chosen together. The XRT-M covers the gateway: battery-powered, sealed to IP68 / NEMA 6P in the M210, and able to send to Digi Axess or your own MQTT broker.
To specify the right part number, request a quote and tell us the tank type, the sensor output (4-20 mA or Modbus), and whether mains is on site. We will match the CSENSE-M210, M210-N or M110 to the site.
Frequently asked questions
What do I need besides the XRT-M for remote tank monitoring?
You need a level sensor with a 4-20 mA or Modbus output, a SIM with a data plan, and either Digi Axess or an MQTT broker to receive the data. The XRT-M reads the sensor and sends the readings over LTE-M or NB-IoT. Choose the antenna and mounting accessories to suit the tank location.
How long do the XRT-M batteries last?
Digi rates the batteries at about five years at two reads and transmits per day. They are dual 7.2 V, 12 Ah lithium thionyl chloride cells, replaceable and not rechargeable. Reporting more often than twice a day shortens the life. Storage discharge is less than 1% per year at 30 °C.
Does the XRT-M work on UK mobile networks?
The XRT-M supports dual-mode LTE-M and NB-IoT on global bands, including B3, B8 and B20. Coverage varies by location and SIM provider. Confirm LTE-M or NB-IoT coverage at the tank before you specify, and check the signal at the mounting point.
Can the XRT-M be used in a hazardous area?
Digi states that the M210 enclosure model carries UL Class I Division 2 certification with corresponding Canadian certifications, plus EN IEC 60079-0:2018 and EN 60079-15:2010. Digi describes it as suitable for Class I and II Division 2 and Class III hazardous locations. The M110 is an IP30 DIN rail module with no hazardous-area claim.
Can the XRT-M monitor more than tank level?
Yes, within its inputs. It reads four analog inputs (4-20 mA or 0-10 VDC), up to four Modbus RTU or ASCII sensors and one digital or pulse input up to 2 kHz. That covers flow through pulse counting, plus pressure, temperature or water quality where the sensor has a supported output.