At a glance
- IP69K tests with 80 °C water at 8 to 10 MPa from close range. IP66 does not cover that, so match the rating to the wash method.
- HACCP is a food-safety management system applied to a site and its processes. No keyboard, display or computer can be HACCP certified.
- Foreign-body control is a design question. Look for no loose or detachable parts, durable legends and materials your hazard analysis accepts.
- Detergents and sanitisers attack seals and legends over time, so ask for chemical compatibility as well as an IP rating.
- Ratings are per model. Confirm the exact variant passed the exact test.
What does a food plant do to technology?
Processing areas are cleaned often and hard. A typical routine starts with a rinse, applies foam detergent, scrubs, rinses again and then sanitises, sometimes with hot water or steam. A terminal in that environment sees direct jets, chemical film, temperature swings and repeated cleaning at shift end.
Meat, dairy, bakery, ready-meal and beverage lines differ in detail. What they share is moisture, fats, sugars and chemicals that office-grade equipment cannot tolerate. Devices sit close to open product in some areas, which adds a second concern: anything that detaches is a potential foreign body.
Which Rugged products suit which part of the plant?
| Area or task | Main concern | Rugged product types to look at |
|---|---|---|
| Raw and high-care processing | Washdown (match each model’s rating to the wash method) | Stainless steel keyboards, panel PCs, panel mount displays |
| Line control and HMI | Sealed front, glove use | Industrial PCs, panel PC displays, trackballs |
| Packing and dispatch | Dust, flour, packaging fragments | Rugged keypads, desktop keyboards |
| Cold rooms and freezers | Low temperature, condensation | Rugged tablets, backlit keyboards |
| Machine integration | Fitting into a builder’s enclosure | OEM rugged computers, OEM rugged keyboards |
| Plant networks and remote sites | Reliable links, serial equipment | Industrial routers, serial connectivity |
How do IP66 and IP69K differ?
The wash method decides the rating. The ingress protection code is defined in BS EN 60529, and the high-pressure, high-temperature test comes from ISO 20653. See IP ratings explained, the IP rating decoder and IP69K and high-pressure washdown.
| Rating | Water test | Suits |
|---|---|---|
| IP65 | Low-pressure water jets from any direction | Splash, light hose-down at distance |
| IP66 | Powerful water jets, 12.5 mm nozzle, 100 litres per minute | Regular hose-down |
| IP67 | Temporary immersion, 30 minutes | Occasional flooding, not a jet rating |
| IP69K | 80 °C water, 8 to 10 MPa, 10 to 15 cm, four angles | High-pressure, hot-water cleaning |
A product may carry IP67 and not IP66 because the tests are separate. If the wash uses jets, confirm that the jet test was passed.
Panel PCs, industrial PCs and displays
A sealed panel PC or display puts a flat front to the wash and keeps electronics behind it. The rating normally applies to the front face when fitted with the supplied gasket to a cutout as specified, so the rating of the installed assembly is what matters. Check the touch technology against wet and gloved hands, and the brightness for the lighting of the area. Browse panel PCs, industrial PCs, panel mount displays and open frame displays for builders integrating their own enclosure.
Mobile computers for stores and goods-in
Handhelds and tablets serve goods-in, stock checks and cold stores. Look for the stated operating temperature range for your coldest zone, a sealed housing and a battery that copes with cold. See rugged tablets; ratings are per model.
Connectivity
Production lines mix modern controllers with older serial equipment. Industrial gateways, serial connectivity and industrial routers bridge them to the plant network, and cellular routers serve remote or temporary sites. Choose hardware with a temperature range and ingress rating that suits where it is mounted, often in a cabinet away from the wash.
Keyboards and pointing devices
Surface finish matters. Smooth, continuous surfaces release soil more readily than textured ones, and crevices around keys or screws collect residue. Stainless steel keyboards are common in washdown areas, but a stainless housing still needs a sealed cable entry and a sealed key surface. The IP code does not tell you how a housing or legend copes with alkaline foams, chlorinated sanitisers or acid descalers, so ask for compatibility against your products at your concentration and contact time.
A conventional mouse is a poor fit for a wet, gloved operator. A trackball fixed into the keyboard or panel stays in place, seals more easily and works with a gloved hand. Capacitive touchpads can fail with water on the surface or thick gloves, so test before you buy. See also panel mount keyboards and keyboard decoders.
Foreign-body control, audits and customer codes
Foreign-body control is part of a site’s hazard analysis, and each device is one item in it. Retailer codes and third-party audit schemes set expectations for equipment in production areas, and they apply to the site. A supplier cannot make a site compliant, but it can provide materials information, ingress test results and construction details to show an auditor. Keep that with your equipment records.
Cases, OEM and services
Specialist cases protect portable instruments in transit. Machine builders can use OEM rugged displays and OEM rugged keypads, and design and customisation covers bespoke legends and layouts. Maintenance and repair and services and expertise cover support.
What to tell us when you ask for a quote
- The real wash method: pressure, temperature, distance, chemicals and frequency.
- The area: high-care, packing, cold room, control room.
- Cleaning agents and sanitisers, with concentrations.
- Any customer or audit requirement for materials, colour or detectability.
- Mounting: panel cutout, bracket or pedestal, and drainage.
- Operating temperature, including cold rooms and hot wash.
- Interface, host system and cable length.
- Quantity and any trial you want before roll-out.
Request a quote or contact us with your wash method and cleaning chemicals.
Related guides and ranges
- IP69K and IPX9 keyboards for high-pressure washdown
- Stainless Steel Keyboards
- Panel PCs
- Rugged Displays
- IP rating decoder
- Cold store and freezer keyboards
Frequently asked questions
What IP rating does food processing equipment need?
It depends on the wash method. IP65 covers low-pressure water jets and is often enough for splash. IP66 covers powerful jets. IP69K, from ISO 20653, covers close-range, high-pressure, hot water. Check how the area is actually cleaned, then choose a rating that tests for that method, and confirm it for the exact model.
Is a HACCP certified keyboard or computer a real thing?
No. HACCP is a food-safety management system built around hazard analysis and controls for a site’s processes. It is applied to the operation, not awarded to a product. A supplier can show materials, ingress ratings and construction, and your hazard analysis decides whether that suits the area.
What does IP69K actually test?
IP69K tests an enclosure with 80 °C water at 8 to 10 MPa and 14 to 16 litres per minute, from 10 to 15 cm, for 30 seconds at several angles. It is a test of ingress under those conditions. It does not test chemical resistance or long-term seal ageing.
How do I reduce foreign-body risk from input devices and terminals?
Choose designs without loose or detachable parts, with legends that will not wear off and cables that are secured and sealed. Agree materials with your food safety team. Detectability, for example colour or detectable materials, is a site decision driven by your hazard analysis.
Can I use stainless steel equipment in a washdown area?
Often yes, as stainless steel tolerates harsh cleaning and is easy to wipe. Check the grade for the chemicals used, the ingress rating of the complete unit, the cable entry and whether the key or touch surface is also sealed. A stainless housing alone does not guarantee washdown suitability.